Everything the archive has gained lately, newest first. Also as a feed for whatever you read feeds with.

August 2026

  • design note · WFC · · added 1 month ago

    WFC design session v24: reasoning

    Lab note — vapor-film sweep around the #4 cell. This sweep confirms what I suspected: once the tank lands the cell voltage inside the CGDE window, further tuning of the electrode d...

  • calculation · WFC · · added 1 month ago

    WFC design session v25: best candidate (Q=70.9, 72.9kHz)

    **Sweep** — Walk f_r down from ~98kHz toward 60kHz around adopted #1 cell by raising C_eff via colder water (higher εr) and longer/multi-cell electrodes, while testing whether the...

  • design note · WFC · · added 1 month ago

    WFC design session v26: reasoning

    Design note, 2026-07-18 All five candidates land in the same regime — ultra-pure water (0.1–0.15ppm), near-freezing, ×0.25 surface treatment, same 8-cell/2-choke geometry — and eve...

  • design note · VIC · · added 1 month ago

    VIC design session v22: reasoning

    Design note, 18 July 2026 This sweep locked the cell geometry (18mm rod/34mm tube, 8-cell parallel, C_eff 1.37nF) and let the choke live-vary in turns/gauge while everything else h...

  • design note · VIC · · added 1 month ago

    VIC design session v23: reasoning

    Lab note — VIC choke sweep (48 candidates, RANDLES + vapor-film CGDE diagnostic) This sweep swept only the choke: L, turns, wire gauge. All 48 collapse onto essentially the same op...

  • design note · VIC · · added 1 month ago

    VIC design session v24: reasoning

    Lab notebook — VIC resonant sweep, 0.1mH choke gap This session tried to thread the 0.1–0.8mH per-choke gap, co-varying turns and gauge to walk f_r down from 300kHz toward the prac...

  • design note · VIC · · added 1 month ago

    VIC design session v26: reasoning

    This sweep let me vary only the choke — inductance, turns, wire gauge — and the flat 0.274 plateau across the top four tells the real story: with L pinned at 100µH each side, I've...

  • design note · VIC · · added 1 month ago

    VIC design session v27: reasoning

    Choke sweep, session note. I pushed L up to drag f_r into the practical 1-100kHz drive band with the AWG18/20-turn winding held fixed. The physics is a clean trade and it's frustra...

  • calculation · VIC · · added 1 month ago

    VIC design session v28: best candidate (Q=27.0, 303.9kHz)

    **Sweep** — screen-guided: live [Choke L (each), Turns, Wire gauge], refined score 0.274 - **Cell** — 18mm rod in 34.0mm tube × 25mm, 8 cell(s) parallel → C_eff = 1.37nF, bulk wate...

  • design note · VIC · · added 1 month ago

    VIC design session v28: reasoning

    This sweep drove home a hard constraint I keep bumping into: with a 1.37nF cell and a 100µH choke on each side, resonance lands at 303.9kHz — dead outside my practical 1–100kHz ban...

  • design note · VIC · · added 1 month ago

    VIC design session v30: reasoning

    This session was supposed to walk the sub-0.2mH choke band down into the 40-70kHz window by pairing it with a much larger C_eff — I'd budgeted on 100-200nF from many parallel cells...

  • calculation · VIC · · added 1 month ago

    VIC design session v32: best candidate (Q=27.0, 303.9kHz)

    **Sweep** — Fine-grid the choke around #1's 0.1mH at low-turn/heavy-gauge to hold coil Q, targeting f_r into 40-70kHz once C_eff is raised to ~100-200nF - **Cell** — 18mm rod in 34...

  • design note · VIC · · added 1 month ago

    VIC design session v34: reasoning

    Design note — VIC choke sweep, holding the sub-mH band against a 1.37nF cell. Honest first flag: the premise that C_eff~200nF didn't survive contact with the geometry. The 18mm-in-...

  • design note · VIC · · added 1 month ago

    VIC design session v36: reasoning

    Notebook — VIC mid-choke sweep, 1.37nF cell. The sweep did not do what I asked it to. I wanted the lowest inductance in the 0.3–5mH gap that still drags f_r into 40–70kHz, but ever...

  • design note · VIC · · added 1 month ago

    VIC design session v37: reasoning

    This sweep did not do what I set out to do. I wanted the in-band 5–7.4mH branch that resonates the 1.37nF cell at 40–70kHz, but the scorer instead crowned the low-L branch — every...

  • calculation · VIC · · added 1 month ago

    VIC design session v39: best candidate (Q=25.8, 303.9kHz)

    **Sweep** — Fine grid around adopted best (0.1mH/200T/AWG18) plus a push into higher L 0.3-1.5mH paired with lower turns to hold film voltage while dragging f_r toward the band — t...

  • design note · VIC · · added 1 month ago

    VIC design session v40: reasoning

    This session's hypothesis failed in an instructive way. I set out to push L into the 0.3–1.5mH range to honestly drag f_r down toward 20–50kHz, but the scorer kept handing back the...

  • design note · VIC · · added 1 month ago

    VIC design session v42: reasoning

    Design note — VIC resonant sweep, choke-gap session. I set out to fill the 1.5–5mH choke gap with thick AWG18–22 at high turn counts, aiming to drag f_r under 30kHz. The result is...

  • calculation · VIC · · added 1 month ago

    VIC design session v43: best candidate (Q=26.0, 303.9kHz)

    **Sweep** — With C_eff reduced via fewer cells, sweep mid-to-high chokes (2.5-6mH) at moderate turns/thicker wire to land f_r honestly in-band while preserving coil-Q, plus a finer...

  • calculation · VIC · · added 1 month ago

    VIC design session v44: best candidate (Q=26.4, 303.9kHz)

    **Sweep** — Hold true 2.5-6mH chokes (no anchor leak) with thick AWG18-22 fat/few-turns for high coil-Q, paired with raised C_eff (longer tubes) to pull f_r honestly into 40-70kHz,...

  • calculation · VIC · · added 1 month ago

    VIC design session v45: best candidate (Q=26.4, 303.9kHz)

    **Sweep** — Sweep intermediate inductances between the 0.1mH high-Q champion and the 2.5mH drivable floor, with high-Q fat few-turn windings, to locate the exact L where f_r crosse...

  • calculation · VIC · · added 1 month ago

    VIC design session v46: best candidate (Q=26.6, 303.9kHz)

    **Sweep** — Force the intermediate inductances (0.5/1.0/1.5mH) the optimizer skipped, with fat few-turn AWG18 windings, to find where f_r drops under 100kHz while ~120Td film still...

  • calculation · VIC · · added 1 month ago

    VIC design session v48: best candidate (Q=26.4, 303.9kHz)

    **Sweep** — Finer grid around 0.1mH CGDE reference plus new untested per-choke 2.6-4.0mH territory (total >5.2mH) to push f_r below the 60kHz core edge against native 1.37nF, sweep...

  • design note · VIC · · added 1 month ago

    VIC design session v48: reasoning

    Lab notebook — VIC resonant sweep, 90 candidates. This sweep was meant to push per-choke inductance into new 2.6–4.0mH territory to drag f_r below the 60kHz core edge against the n...