Skip to content
Stan’s Legacy The Stanley Meyer Archive

The archive

What’s new

Everything the archive has gained lately, newest first. Also as a feed for whatever you read feeds with.

August 2026

  • design note · WFC · · added 1 month ago

    WFC design session v33: reasoning

    Lab note — CGDE-window sweep, Randles floor. This run was supposed to walk the vapor-film field down into the 80–250 Td cold-chemistry window by shrinking the gap (sub-3mm) and dri...

  • design note · WFC · · added 1 month ago

    WFC design session v36: reasoning

    This sweep tried to light the vapor film from the water side — drop gap, chill to 4°C, and run 0.2ppm ultrapure so a modest drive lands in the cold-chemistry window — and it expose...

  • design note · WFC · · added 1 month ago

    WFC design session v38: reasoning

    This sweep was supposed to hunt the 700-900V Paschen knee and land the vapor-film in the 80-250 Td cold-chemistry window. It didn't quite. Every top candidate lands at ~886-901V ce...

  • design note · VIC · · added 1 month ago

    VIC design session v106: reasoning

    All five top candidates are effectively the same cell and choke; only duty separates #1–#4 (2/4/8/15%) and #5 swaps to a 620-turn choke. That degeneracy is itself the finding: the...

  • design note · WFC · · added 1 month ago

    WFC design session v40: reasoning

    Lab note — WFC resonant sweep, surface-treatment as the fresh lever. The finer grid confirms the 10mm-in-12mm × 60mm cell as the sweet spot: C_eff 1.58nF resonating my 0.9mH chokes...

  • design note · VIC · · added 1 month ago

    VIC design session v107: reasoning

    This sweep set out to walk peak_v down to land V_cell near 500V, 150-250 Td, with Faradaic leakage under 10mA. It did not get there — and that's the honest headline. Every top cand...

  • calculation · WFC · · added 1 month ago

    WFC design session v40: best candidate (Q=56.5, 94.5kHz)

    **Sweep** — Finer grid at the 10-12mm×60mm best but use surface_factor as the fresh lever to raise C_dl and hold displacement current while low peak_v + cold pure water crush leaka...

  • calculation · WFC · · added 1 month ago

    WFC design session v48: best candidate (Q=14.2, 89.9kHz)

    **Sweep** — Deliberately lower magnification via larger rod OD + wider annular gap to break the ×70 floor, then sweep gamma_se with moderated peak_v/duty to land V_cell at 500-600V...

  • calculation · VIC · · added 1 month ago

    VIC design session v112: best candidate (Q=86.0, 95.4kHz)

    **Sweep** — Hold the AWG18 1mH/200T champ with a fine choke grid and walk peak_v down from bench-proven 120V to land the 470 Td film inside the 80-250 Td CGDE band via lower magnif...

  • calculation · WFC · · added 1 month ago

    WFC design session v44: best candidate (Q=89.2, 98.4kHz)

    **Sweep** — Lower Q via larger rod OD + wider annular gap while trimming peak_v/duty together to push V_cell down from 837V/334Td into the 80-250 Td CGDE window, holding Faradaic l...

  • calculation · VIC · · added 1 month ago

    VIC design session v109: best candidate (Q=24.5, 94.6kHz)

    **Sweep** — Walk peak_v DOWN from bench-proven 120V while holding the AWG18 1mH champ (plus two slightly softer chokes) to drag the 470 Td film back into the 80-250 Td CGDE band an...

  • calculation · VIC · · added 1 month ago

    VIC design session v80: best candidate (Q=24.8, 303.9kHz)

    **Sweep** — Map the untouched 0.1-1mH transition between the physics-ideal 100µH reference and the buildable 1mH floor at high-Q gauges, to see where film lighting decays as L clim...

  • design note · VIC · · added 1 month ago

    VIC design session v91: reasoning

    Ran the 32-50 kHz seam hunt, but honesty first: the optimizer ignored my intent. I asked for 1-2 cells (C_eff ~1.37 nF) to push f_r up into the 32-50 kHz band; every surviving cand...

  • design note · WFC · · added 1 month ago

    WFC design session v29: reasoning

    This sweep pins the v19 tank (1.29nF cell, 0.99mH/129T choke) and walks the drive ladder, so Q, f_r, and voltage magnification are all frozen at Q=101.2, f_r=99.41kHz, ×101.2 gain....

  • design note · WFC · · added 1 month ago

    WFC design session v28: reasoning

    This sweep set out to pin the 150 Td cold-window from the density side, and I'll be honest: it didn't get there. Every top candidate lands at 572 Td (1434V film) or 1144 Td (2868V)...

  • design note · WFC · · added 1 month ago

    WFC design session v31: reasoning

    Lab note — annular-gap widening sweep, 7776 candidates. The stated goal was to slide the 0.1mm vapor film down into the 80–250 Td cold-chemistry window by opening the gap to 6–9mm...

  • calculation · VIC · · added 1 month ago

    VIC design session v102: best candidate (Q=7.0, 94.9kHz)

    **Sweep** — Raise coil Q with tighter AWG24 chokes at fewer turns to pull f_r into 55-75kHz, lifting V_cell toward ~150 Td at the adopted 60V sub-breakdown drive, with a couple sho...

  • design note · VIC · · added 1 month ago

    VIC design session v100: reasoning

    Sweep note — VIC vapor-film tuning, 1440 candidates at resonance. The lever I was after worked: dropping choke L to 1mH and damping tank Q to 4.0 pulls V_cell down to ~288V, and th...

  • calculation · VIC · · added 1 month ago

    VIC design session v103: best candidate (Q=6.7, 85.7kHz)

    **Sweep** — At adopted 60V sub-breakdown drive, raise L on AWG24 chokes to pull f_r from 94.87 kHz down into 55-75 kHz and land the vapor film in the 80-250 Td cold-chemistry windo...

  • calculation · VIC · · added 1 month ago

    VIC design session v104: best candidate (Q=7.3, 90.0kHz)

    **Sweep** — Finer grid around the adopted AWG22 0.7 mH tank plus higher-L/higher-turn territory to push f_r below 85 kHz, sweeping low-duty low-peak drive to trend Faradaic leakage...

  • design note · WFC · · added 1 month ago

    WFC design session v32: reasoning

    This sweep was supposed to land the vapor-film inside the 80-250 Td cold-chemistry window by dropping cell voltage. It didn't. Every top candidate lights the 0.1mm film at ~318-319...

  • calculation · WFC · · added 1 month ago

    WFC design session v35: best candidate (Q=30.6, 92.7kHz)

    **Sweep** — Cut peak_v into the 24-90V band paired with low duty to slide V_cell toward the 80-250 Td window while holding the cold/pure/passivated Randles floor, with a fine grid...

  • calculation · VIC · · added 1 month ago

    VIC design session v105: best candidate (Q=7.9, 99.8kHz)

    **Sweep** — Push f_r into 55-75kHz with higher-L AWG24 chokes and drop peak_v to walk vapor-film Td down into the 80-250 cold-chemistry window, sweeping duty widely to break degene...

  • calculation · WFC · · added 1 month ago

    WFC design session v37: best candidate (Q=51.1, 84.5kHz)

    **Sweep** — Deliberately lower Q and trim peak_v to pull V_cell into ~250-400V, widen gap sweep to drop film Paschen and land Td inside 80-250, holding purer/colder water for a low...

  • calculation · WFC · · added 1 month ago

    WFC design session v42: best candidate (Q=69.7, 97.7kHz)

    **Sweep** — Hold adopted 10/1/55mm cell (0.1ppm/2C/x0.25) and attack peak_v alone — sweep drive down to land V_cell at 500-600V/~180Td CGDE window, matched ultra-low duty, checking...

  • calculation · WFC · · added 1 month ago

    WFC design session v49: best candidate (Q=86.6, 95.4kHz)

    **Sweep** — Slide V_cell into the 80-250 Td sub-critical corner (M 0.1-1) by softening tank Q with cold/pure water while trimming gamma_se and peak_v together — the water/thermal p...

  • calculation · WFC · · added 1 month ago

    WFC design session v50: best candidate (Q=88.7, 95.1kHz)

    **Sweep** — Lower effective Q via colder/purer water and sweep gamma_se + moderated peak_v together to slide V_cell into the 80-250 Td / M 0.1-1 sub-critical corner instead of magn...

  • calculation · WFC · · added 1 month ago

    WFC design session v45: best candidate (Q=92.1, 98.2kHz)

    **Sweep** — Co-sweep water/electrode Randles levers (purity, temperature, surface treatment) with moderated peak_v/duty at near-best 10mm/50mm geometry to slide V_cell down from 83...

  • design note · EPG · · added 1 month ago

    EPG design session v3: reasoning

    Base-grid sweep, 20,736 candidates, scoring on a blend of net output and efficiency. I was varying bore, loop length, coil count and turn-count, spiral pitch, and holding the mediu...

  • calculation · VIC · · added 1 month ago

    VIC design session v116: best candidate (Q=47.7, 98.6kHz)

    **Sweep** — screen-guided: live [Choke L (each), Turns, Wire gauge], refined score 0.616 - **Cell** — 10mm rod in 14.0mm tube × 50mm, 2 cell(s) parallel → C_eff = 1.42nF, bulk wate...