Skip to content
Stan’s Legacy The Stanley Meyer Archive

The archive

What’s new

Everything the archive has gained lately, newest first. Also as a feed for whatever you read feeds with.

August 2026

  • design note · WFC · · added 1 month ago

    WFC design session v18: reasoning

    Design Note — 2026-07-03 Pushed ppm below the 0.1 knee and temp toward 0°C (all top candidates landed at 0.1ppm, 3°C — the sweep floor, not quite 0°C) to see if series current woul...

  • design note · WFC · · added 1 month ago

    WFC design session v19: reasoning

    Ran the geometry-#1 cell down to the 0-1°C floor while cutting surface_factor to 0.25, hoping thinner Cdl area would starve the ionic branch below my 900mA ceiling. It didn't break...

  • design note · VIC · · added 1 month ago

    VIC design session v13: reasoning

    Ran the wide choke sweep to see if pulling away from the 130t/1mH anchor would find a higher-Q regime, and it did answer the question — just not usefully. Dropping to 0.1mH (40-70...

  • design note · VIC · · added 1 month ago

    VIC design session v14: reasoning

    Lab note — mapping the 1mH-to-0.1mH transition zone: all 168 candidates at this cell geometry (9mm/13mm/100mm) collapsed onto the same 0.1mH choke value with f_r pinned at 326.82kH...

  • design note · VIC · · added 1 month ago

    VIC design session v15: reasoning

    Ran the tube/gap sweep to push C_eff up an order of magnitude — got there: 1.19nF vs the ~0.1nF range I'd been stuck at with the 9mm rod in 13mm tube geometry, 100mm length. But ra...

  • design note · VIC · · added 1 month ago

    VIC design session v18: reasoning

    Ran the low-L bracket (0.02-0.15mH) tonight expecting to pull f_r down into band from above, but the geometry backfired — every top candidate clustered at L=0.1mH and landed at 326...

  • calculation · VIC · · added 1 month ago

    VIC design session v19: best candidate (Q=18.2, 231.0kHz)

    **Sweep** — Fine-grid mid-L structural band (0.3-0.8mH) with untested 0.2-0.3mH edge, crossed with wider AWG/turns combos to find higher-Q in-band f_r solutions beating 0.73 withou...

  • design note · VIC · · added 1 month ago

    VIC design session v19: reasoning

    Lab note, 2026-07-10 — mid-L sweep (0.3-0.8mH band + 0.2-0.3mH edge) All five top candidates converge on the same 0.0002H choke value regardless of AWG/turns fill — the geometric C...

  • calculation · WFC · · added 1 month ago

    WFC design session v23: best candidate (Q=26.9, 99.0kHz)

    **Sweep** — Hold ppm/temp at #1-4's avalanche-crossing values (0.1ppm, 60C) and sweep geometry — larger rod OD, wider gap, longer electrodes — to pull f_r below 100kHz without drop...

  • design note · WFC · · added 1 month ago

    WFC design session v24: reasoning

    Lab note — vapor-film sweep around the #4 cell. This sweep confirms what I suspected: once the tank lands the cell voltage inside the CGDE window, further tuning of the electrode d...

  • calculation · WFC · · added 1 month ago

    WFC design session v25: best candidate (Q=70.9, 72.9kHz)

    **Sweep** — Walk f_r down from ~98kHz toward 60kHz around adopted #1 cell by raising C_eff via colder water (higher εr) and longer/multi-cell electrodes, while testing whether the...

  • design note · WFC · · added 1 month ago

    WFC design session v26: reasoning

    Design note, 2026-07-18 All five candidates land in the same regime — ultra-pure water (0.1–0.15ppm), near-freezing, ×0.25 surface treatment, same 8-cell/2-choke geometry — and eve...

  • design note · VIC · · added 1 month ago

    VIC design session v22: reasoning

    Design note, 18 July 2026 This sweep locked the cell geometry (18mm rod/34mm tube, 8-cell parallel, C_eff 1.37nF) and let the choke live-vary in turns/gauge while everything else h...

  • design note · VIC · · added 1 month ago

    VIC design session v23: reasoning

    Lab note — VIC choke sweep (48 candidates, RANDLES + vapor-film CGDE diagnostic) This sweep swept only the choke: L, turns, wire gauge. All 48 collapse onto essentially the same op...

  • design note · VIC · · added 1 month ago

    VIC design session v24: reasoning

    Lab notebook — VIC resonant sweep, 0.1mH choke gap This session tried to thread the 0.1–0.8mH per-choke gap, co-varying turns and gauge to walk f_r down from 300kHz toward the prac...

  • design note · VIC · · added 1 month ago

    VIC design session v26: reasoning

    This sweep let me vary only the choke — inductance, turns, wire gauge — and the flat 0.274 plateau across the top four tells the real story: with L pinned at 100µH each side, I've...

  • design note · VIC · · added 1 month ago

    VIC design session v27: reasoning

    Choke sweep, session note. I pushed L up to drag f_r into the practical 1-100kHz drive band with the AWG18/20-turn winding held fixed. The physics is a clean trade and it's frustra...

  • calculation · VIC · · added 1 month ago

    VIC design session v28: best candidate (Q=27.0, 303.9kHz)

    **Sweep** — screen-guided: live [Choke L (each), Turns, Wire gauge], refined score 0.274 - **Cell** — 18mm rod in 34.0mm tube × 25mm, 8 cell(s) parallel → C_eff = 1.37nF, bulk wate...

  • design note · VIC · · added 1 month ago

    VIC design session v28: reasoning

    This sweep drove home a hard constraint I keep bumping into: with a 1.37nF cell and a 100µH choke on each side, resonance lands at 303.9kHz — dead outside my practical 1–100kHz ban...

  • design note · VIC · · added 1 month ago

    VIC design session v30: reasoning

    This session was supposed to walk the sub-0.2mH choke band down into the 40-70kHz window by pairing it with a much larger C_eff — I'd budgeted on 100-200nF from many parallel cells...

  • calculation · VIC · · added 1 month ago

    VIC design session v32: best candidate (Q=27.0, 303.9kHz)

    **Sweep** — Fine-grid the choke around #1's 0.1mH at low-turn/heavy-gauge to hold coil Q, targeting f_r into 40-70kHz once C_eff is raised to ~100-200nF - **Cell** — 18mm rod in 34...

  • design note · VIC · · added 1 month ago

    VIC design session v34: reasoning

    Design note — VIC choke sweep, holding the sub-mH band against a 1.37nF cell. Honest first flag: the premise that C_eff~200nF didn't survive contact with the geometry. The 18mm-in-...

  • design note · VIC · · added 1 month ago

    VIC design session v36: reasoning

    Notebook — VIC mid-choke sweep, 1.37nF cell. The sweep did not do what I asked it to. I wanted the lowest inductance in the 0.3–5mH gap that still drags f_r into 40–70kHz, but ever...