observation · Voltage Intensifier Circuit · computed
#3487's 127.2 mH "opposing" was a second series-AIDING reading (hookup error, confirmed by Scotchn): LCR repeatability on aiding ≈ 1.6%
Scotchn confirmed (Discord #neuralstan20-testing 2026-10-05) that the 127.2 mH reading came from a hookup that had ended up series-aiding again. #3487's sum-rule violation is therefore void. Aiding readings 129.3 and 127.2 mH give about 1.6% repeatability on the 160.4 Hz meter. With opposing at 0.137 mH: M = 31.8 to 32.3 mH, L_A + L_B = 63.7 to 64.7 mH, k ≈ 0.998 either way. The singles (59.9 mH total) are still 6 to 7% below the series-derived sum, more than the repeatability, so that gap is real and open: core µ depending on drive level, or the meter.