Skip to content
Stan’s Legacy The Stanley Meyer Archive

Figure (11-1)

Figure (11-1)

How it is written

  • (11-1) 11×

Drawings 3

On this figure 11

Where it is named · 11

Water Metering Valve Assembly 1×

  1. Figure series 11 of Memo WFC 423 DA, "RE: Water Fuel Injector System": the water metering valve, drawn as an assembly (11-1) and then part by part. Sheets 11-1 and 11-5 were scanned sideways and 11-6 to 11-9 upside down; they are shown here the right way up. 11-8A and 11-8B are on a separate sheet without the memo's header, a redrawing of the coil cap and the assembled terminal end.

    Read it there →

Wobbling Effect 2×

  1. … lectrical charged sub-particles of the atom and the recurring pulsating electrical voltage fields (E15/E16) of opposite electrical polarity of potential (B+/B-), as so illustrated in (1020) of Figure (11-1) titled “Neutron Electrical Polarization Process” as to Figure (10-1) titled “Voltage Intensifier Circuit”.

    Read it there →

  2. The surplus electromagnetic energy (gamma ray absorption), if any, is simply absorbed into the energy spectrum of the atom when the atom transmutes into another element (s) during the Neutron Electrical Polarization Process, as so illustrated in (1020) of Figure (11-1).

    Read it there →

Voltage Flexing Process 2×

  1. In order to accomplish this task, dual unipolar voltage pulse circuit (1010) of Figure (11-1) is, now, utilized to deflect (Physical Movement) the bipolar electrically charged water molecule (210) of Figure (3-46) while undergoing and experiencing both physical and electrical stress, simultaneously

    Read it there →

  2. dual unipolar voltage pulse circuit (1010) of Figure (11-1)

    Read it there →

VIC Switchover Circuit 6×

  1. VIC Switchover Circuit (1010) of Figure (11-1) is utilized to bring about Voltage Flexing Process (1050) by preventing amp influxing into and away from the separate and periodically spaced (-) voltage zones (E13-EI4 - E15-EI6) of diagram (1030) of Figure (11-3) as to (1010) of Figure (11-1);

    Read it there →

  2. VIC Switchover Circuit (1010) of Figure (11-1) is utilized to bring about Voltage Flexing Process (1050) by preventing amp influxing into and away from the separate and periodically spaced (-) voltage zones (E13-EI4 - E15-EI6) of diagram (1030) of Figure (11-3) as to (1010) of Figure (11-1);

    Read it there →

  3. VIC Switchover Circuit (1010) of Figure (11-1)

    Read it there →

  4. Electrically interfacing alternate "Switchover" voltage pulse wave-form (T4A/T4B) to each of both VIC Coil-Array (s) (1002/1003) of Figure (11-3) as schematically depicted, now, forms VIC Switchover Circuit (1010) of Figure (11-1).

    Read it there →

  5. Pairing together positive voltage zone (E13/952) with negative voltage zone (E16/956) and doing the same with voltage-surfaces (E14/953) to (E15/954) as so graphically shown in (1O1O) of Figure (11-1) and each having an longitudinal axis of identical length, now, individually forms what is called hereinafter a "Differential Voltage Wave-guide" (1040)

    Read it there →

  6. In like manner as to linear cylindrical resonant cavity (730) of Figure (7-12), the Differential Voltage Wave-Guide (1040) of (1010) of Figure (11-1) as to Figure (11-6) is constructed in such a way as to allow a smaller tube to be placed inside a much larger tube having space relationship to allow water to pass there between, as so pictorially shown in (170) of Figure (3-25).

    Read it there →